Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Rev. bras. ortop ; 57(6): 962-967, Nov.-Dec. 2022. graf
Artigo em Inglês | LILACS | ID: biblio-1423638

RESUMO

Abstract Objective To evaluate the long-term results of valgus intertrochanteric osteotomy fixed with double angled dynamic hip screw for nonunion fracture of the neck of the femur in young adults. This implant allows more freedom of fixation in the sagittal plane. Very few studies have evaluated the long-term outcome for treatment of nonunion in fractures of the neck of the femur. Methods This is a prospective interventional study that included 20 patients with nonunion of the fracture of the neck of the femur aged < 60 years old without avascular necrosis of the head and significant resorption of the neck of the femur. A lateral closing wedge osteotomy was performed just above the lesser trochanter after inserting the Richard screw across the nonunion site, and it was fixed with a double-angle 120° barrel plate. The outcome was evaluated using union rate and the Harris Hip Score for functional outcome. Results The average postoperative decrease in the Pauwels angle was of 28.9°. A total of 80% of the cases progressed to union within a mean duration of 7.53 months. The mean Harris Hip Score at the final follow-up was 86.45. Conclusion Valgus intertrochanteric osteotomy and fixation with a double angled dynamic hip screw is a reliable and effective method for preservation of head and promoting union in an ununited fractured neck of the femur in young patients.


Resumo Objetivo Avaliar os resultados a longo prazo da osteotomia intertrocantérica valgizante, fixada com parafuso dinâmico de quadril (DHS, na sigla em inglês) de ângulo duplo, em fraturas não consolidadas do colo femoral em adultos jovens. Este implante permite uma liberdade maior de fixação no plano sagital. Muito poucos estudos avaliaram o desfecho do tratamento a longo prazo da fratura não consolidada do colo femoral. Métodos Trata-se de um estudo prospectivo de intervenção que incluiu 20 pacientes com fratura não consolidada do colo femoral com idade < 60 anos, sem necrose avascular da cabeça femoral e significativa reabsorção do colo femoral. Foi realizada uma osteotomia em cunha de fechamento lateral logo acima do trocânter menor após a inserção do parafuso tipo Richard no sítio do retardo da consolidação óssea, sendo fixada com uma placa cilíndrica de ângulo duplo de 120°. O resultado foi avaliado com o uso da taxa de consolidação e da escala Harris Hip Score quanto ao desfecho funcional. Resultados Foi obtida uma redução pós-operatória média de 28,9° do ângulo de Pauwels. Os casos que evoluíram para a consolidação alcançaram 80%, em um período médio de 7,53 meses. A média da escala Harris Hip Score foi de 86,45 no acompanhamento final. Conclusão A osteotomia intertrocantérica valgizante e a fixação com DHS de ângulo duplo é um método confiável e eficaz para a preservação da cabeça do fêmur, promovendo a consolidação de uma fratura não consolidada do colo femoral em pacientes jovens.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Osteotomia , Avaliação de Processos e Resultados em Cuidados de Saúde , Fraturas do Colo Femoral/cirurgia , Colo do Fêmur/cirurgia , Colo do Fêmur/lesões , Fraturas não Consolidadas
2.
Rev. bras. ortop ; 54(6): 746-750, Nov.-Dec. 2019. graf
Artigo em Inglês | LILACS | ID: biblio-1057947

RESUMO

Abstract Isolated anterior dislocation of the radial head is rarely reported. To date, only five cases have been reported in the world literature. In all of these cases, the patients presented with restricted supination-pronation movements of the forearm with maintained elbow flexion-extension. We report an unusual case of isolated anterior radial head dislocation in an 18-year-old male, who presented with maintained supination-pronation movements of the forearm but restricted elbow flexion-extension. Closed reduction was attempted, but it failed. Hence, an open reduction was performed. However, the reduction was unstable due to rupture of the annular ligament. Hence, the repair of the annular ligament was performed, and a radio-ulnar Kirschner wire was passed to maintain the reduction of the proximal radio-ulnar joint, thus keeping the annular ligament stress-free, facilitating its healing. At 12 months of follow-up, the patient had normal elbow function and complete range of motion.


Resumo A literatura sobre a luxação anterior isolada da cabeça do rádio é escassa, com apenas cinco casos relatados no mundo inteiro até hoje. Em todos esses casos, os pacientes apresentaram movimentos de supinação-pronação restritos do antebraço, e manutenção da flexão-extensão do cotovelo. Os autores apresentam um caso incomum de luxação de cabeça radial anterior isolada em um paciente do sexo masculino de 18 anos, que apresentou movimentos de supinação-pronação no antebraço e restrição na flexão-extensão do cotovelo. A redução fechada foi tentada, mas sem sucesso. Assim, foi feita a redução aberta. No entanto, a redução foi instável devido à ruptura do ligamento anular. Por isso, o reparo do ligamento anular foi realizado, e um fio de Kirschner rádio-ulnar foi inserido para manter a redução da articulação rádio-ulnar proximal, evitando estresse sobre o ligamento anular, facilitando sua cicatrização. Aos 12 meses de acompanhamento, o paciente apresentava função normal do cotovelo e amplitude de movimento completa.


Assuntos
Humanos , Masculino , Adolescente , Rádio (Anatomia) , Amplitude de Ondas Sísmicas , Luxações Articulares , Articulação do Cotovelo , Redução Fechada , Redução Aberta , Ligamentos Articulares
3.
Artigo | IMSEAR | ID: sea-185360

RESUMO

Despite being extensively used, k wires have their own set of complications, with loosening and eakage of these wires being the most significant one of them. We report a case of patella fracture treated with tension band wiring (TBW). After achieving fracture union, patient was lost to follow up. He reported four years later with a oken k–wire which had migrated posteriorly into the popliteal fossa and had to be removed as it was causing symptoms to the patient. We recommend following certain steps to prevent the occurrence of such a complication: following AO principles of fracture fixation, encouraging hardware removal after union of fracture wherever possible, close clinical and radiological follow up to detect the movement, eakage and migration of wires at the earliest and removal of migrated wires on priority basis, irrespective of patient being symptomatic or asymptomatic.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA